Network settings in VIOSO 6
Last updated
Last updated
These settings apply when multiple instances of VIOSO 6 are connected via network to execute scalable calibrations.
Access from Menu > Options > Settings > Multi client
:
These settings should be checked and adjusted whenever a new configuration of PCs is made, or if changes in the network happened.
Check "Enable" to enable multiclient functionality
Adapter: Select the network interface - in case you have multiple NICs on your system
All VIOSO 6 instances must use the adaptor from the same network. E.g.: PC1: 192.168.49.10, PC2: 192.168.49.11, etc This will not work: PC1: 192.168.0.10 , PC2: 192.168.20.11
These settings should be be left as is, so do change them only if there are issues within the network:
Control Port and Information Port: These ports are required for the communication bewtween the VIOSO instances. Do not change unless they conflict with other applications on the same PCs.
Defaults ports as of VIOSO 6.0):
Control: 8417
Information: 8517
Changes of Control Port
and Information Port
must be done on all PCs in the same way!
Receive Buffer: Change only if there are issues due to the networking hardware
Subnet mask clamp: Change only if required by the network adress scheme
These settings apply to remote control VIOSO 6 by external applications.
Access from Menu > Options > Settings > Remote Control
:
The TCP and UDP interfaces are enabled by default, listening all network adapters.
Change the adapter from 0.0.0.0 (all adapters) to a specific adapter to restrict the remote control functionality to this network interface
Change the ports in case of issues or conflicts with other applications.
Defaults ports as of VIOSO 6.0):
TCP: 8317
UDP: 817